Product Description
Function:
Real-time measurement and indication on AC or DC voltage(current) in an electric circuit; Program mable CT/PT ratio; Higher and lower limit alarm output and programmable rely time of alarm.
Size:
96*96mm, 48*48mm, 96*48mm. 72*72mm
Basic parameters:
Measuring range:
AC voltmeter AC 10 ~ 600V, external PT is necessary if more than 600V
DC voltmeter DC 10 ~ 600V
Accuracy: ± (0.5%FS+1 digit)
Measuring display mode: 4 LED nixietube effective value display
Resolution: Last figure one digit
Overflow indication: The top digit display "1" or "-1" and other digit hiding
Auxiliary power supply: AC 220V± 10%
Alarm contact capacity: AC250V/1A
Alarm Shift Difference: 0.1%FS~50.0%FS
Alarm delay time: 0.0~99.9s programmable
Terminal arrangement and wiring connection:
( Attention: If it is not the same with the wiring schema of the diagram behind case, please accord to the one of diagram behind case)
POWER: Auxiliary power input port of instrument, Auxiliary power supply is AC 220V± 10% (please note if you need special power supply).
INPUT: Signal input port of instrument, HI represents"+" port of DC input signal, fire wire terminal of AC voltage input signal and inlet wire terminal
Of AC current input signal.
LO: "-" port of DC input signal, the other one wire of AC voltage input signal; The outlet wire terminal of AC current signal input
OUT: The alarm contact output port of meter
Technical Index |
Accuracy of measurement |
Electric current 0.5 |
Singal input |
Connection mode of single phase |
|
Rated voltage of AC 57.7V, AC 100V, AC 220V, AC 380V, DC 2V, DC 20V, DC 200V, DC 600V, DC600V |
|
Over load 1.2 times ( Continued ), 2 times / second ( instantaneous ) |
|
Power < 1VA/ phase |
|
Impedance > 300KΩ |
|
The frequency of 45~65Hz or DC |
Auxiliary power supply |
AC/DC 80V~270V, AC220V, AC380V, AC100V, DC48V, DC 24V |
|
Power consumption < 4VA |
Function module |
Communication interface 1 way RS-485 communication, Modbus-RTU protocol |
|
Baud rate: 1200~9600bps, the default 2400bps |
|
Switch input support 2 stem node input |
|
The switch output support 2 relay output, capacity: AC 250V/5A, DC 30V/5A |
|
Transmission output support 1 analog output: 0/4~20mA or 0~5/10V |
Environment |
Working temperature: -10° C ~+55° C |
|
Storage temperature: -25° C ~+70° C |
|
Relative humidity is less than 93%, no corrosive gas |
|
Elevation≤ 2500m |
Safety |
Insulation resistance > 100MΩ |
|
AC withstand voltage AC 2KV |
Electromagnetic compatibility |
ESD level 4 |
|
Electrical fast transient burst level 4 |